1
00:00:06,430 –> 00:00:14,850
The Concise RDWorks Learning Lab with Russ Sadler, Session 5: The High Voltage Power Supply.
2
00:00:14,850 –> 00:00:19,720
Now, here’s our simplified diagram of the tube and the high voltage power supply.
3
00:00:19,720 –> 00:00:26,050
Now, in the previous session, I did indicate to you that the high voltage power supply has got two functions.
4
00:00:26,050 –> 00:00:33,550
One, it has to supply high voltage here, 25000 volts ish.
5
00:00:33,550 –> 00:00:43,030
It varies depending on the tube length and various other things to get the nitrogen in the gas mix to ionize.
6
00:00:43,030 –> 00:00:55,030
Once the gas is ionized, it changes away from being a non conductive material to being a highly conductive material, just like a piece of wire.
7
00:00:55,030 –> 00:00:59,660
And so now we have got a circuit which can carry huge amounts of current.
8
00:00:59,660 –> 00:01:03,160
But this is where the second function of the power supply comes in.
9
00:01:03,160 –> 00:01:11,200
Somewhere in here we’ve got something that is a bit like a variable resistor that can be
10
00:01:11,200 –> 00:01:19,000
programed by the controller to allow different amounts of current to flow in this circuit.
11
00:01:19,000 –> 00:01:26,110
Now, as I indicated in the previous session, if you’ve bought a machine from eBay, a supposed 50 watt machine,
12
00:01:26,110 –> 00:01:30,670
it’s an almost certainty that you have got an 800 millimeter long,
13
00:01:30,670 –> 00:01:39,610
40 watt tube. And it will be supplied with one of these pretty cheap, hmmm it’s a sort of a universal power supply,
14
00:01:39,610 –> 00:01:47,470
which can be used in the analog controller machines like the K40.
15
00:01:47,470 –> 00:01:55,330
It can also be used with a digital control system. Now, here is one of those power supplies that I took out of another machine.
16
00:01:55,330 –> 00:02:01,690
And in this instance, it says it’s 50 watt. Well, maybe it is, maybe it’s not.
Transcript for High Voltage Laser Power Supply (Cont…)
17
00:02:01,690 –> 00:02:10,420
But it’s still one of these universal power supplies which has got these connections here for like a K40 machine,
18
00:02:10,420 –> 00:02:16,780
which doesn’t have a digital controller. These connections here will allow you to use a digital controller.
19
00:02:16,780 –> 00:02:24,310
And here we’ve got the mains input connections. So these are basically mains voltage – dangerous.
20
00:02:24,310 –> 00:02:29,140
And these here are all about five volts DC. So they’re not dangerous at all.
21
00:02:29,140 –> 00:02:35,470
So if you’ve got a different set of connections to this and any replacement power supply will have,
22
00:02:35,470 –> 00:02:43,630
you will have to look up your power supply and it will give you a wiring specification, which I’ll talk about in a minute.
23
00:02:43,630 –> 00:02:56,320
Now, inside the power supply, we can see here this white thing with this red cable coming out. The red cable is
24
00:02:56,320 –> 00:03:02,770
the clue. This is the high voltage generator, it’s called a flyback transformer.
25
00:03:02,770 –> 00:03:14,530
Some high voltage power supplies have one, because for a low wattage tube, you don’t need too much voltage, it may well only require 18 or 20000 volts.
26
00:03:14,530 –> 00:03:21,100
Whereas when you get a slightly bigger tube, maybe a 60, 70, 80 or 100, watt tube or even more,
27
00:03:21,100 –> 00:03:28,990
it might have two or even three of these in it, to boost the voltage up to the correct voltage. Basically,
28
00:03:28,990 –> 00:03:39,850
this is a fairly crude mechanism an inductor type system, a transformer which allows you to put low voltage in and get high voltage out.
29
00:03:39,850 –> 00:03:48,640
But it takes time for this to happen. This process here is not an instant process.
30
00:03:48,640 –> 00:03:53,320
If we take a look through there, we can see all sorts of electronic components.
31
00:03:53,320 –> 00:04:00,160
Electronic components work at microseconds or even nanosecond times.
Transcript for High Voltage Laser Power Supply (Cont…)
32
00:04:00,160 –> 00:04:05,470
This is a thousand times slower at a millisecond.
33
00:04:05,470 –> 00:04:09,610
So we’ve got two conflicting things happening inside here.
34
00:04:09,610 –> 00:04:15,550
We’ve got rapid electronic switching and pretty slow high voltage output.
35
00:04:15,550 –> 00:04:21,610
Some devices will tell you what the maximum output current of the device is.
36
00:04:21,610 –> 00:04:26,890
This one doesn’t, so you’ll have to go onto a website and hunt for that information.
37
00:04:26,890 –> 00:04:35,330
Here we’ve got Maximum output current, 20 milliamps D.C., so 20 milliamps,
38
00:04:35,330 –> 00:04:40,430
if you look back at my chart previously, you’ll find that that will run a 50 watt tube.
39
00:04:40,430 –> 00:04:44,540
So the maximum output voltage of this is 23 kilovolts.
40
00:04:44,540 –> 00:04:55,280
What that means is you need to make sure that your tube has got a switching triggering voltage less than this because you need to trigger it at,
41
00:04:55,280 –> 00:05:00,500
say, 20kV. And this will go up to 23 K.V. kilovolts.
42
00:05:00,500 –> 00:05:11,300
So here’s something called response speed. And basically what this means is if you’ve asked for your program to deliver, say, 60 percent power,
43
00:05:11,300 –> 00:05:20,160
it will get to 90 percent of 60 percent power, 54 percent power in less than or equal to one millisecond.
44
00:05:20,160 –> 00:05:28,190
You might think that ah a thousandths of a second is quite fast. We’ll put that thousandth s of a second into some sort of perspective in a minute.
45
00:05:28,190 –> 00:05:35,630
But before we do that, let me just try and explain to you how this power supply operates.
46
00:05:35,630 –> 00:05:44,690
Now, one of the main misunderstandings that I’ve experienced with people coming to this new, is that you’ve got a 50
47
00:05:44,690 –> 00:05:55,100
watt tube and you’ve got a controller and the controller shows you anything between zero and 100 percent power.
48
00:05:55,100 –> 00:05:58,520
So if I’ve got a 50 watt tube,
Transcript for High Voltage Laser Power Supply (Cont…)
49
00:05:58,520 –> 00:06:10,160
I would expect to get 50 watts out at 100 percent power and I would expect to get 25 watts out at 50 percent power – wrong!
50
00:06:10,160 –> 00:06:12,260
That’s not the way it works.
51
00:06:12,260 –> 00:06:23,750
There is no direct relationship between percent power from the controller or your program and the watts coming out of your tube.
52
00:06:23,750 –> 00:06:29,920
The controller turns percent power into a signal.
53
00:06:29,920 –> 00:06:40,610
Zero volts, zero percent power, 100 percent power, five volts D.C. down this line here.
54
00:06:40,610 –> 00:06:50,330
So 50 percent power is 2.5 volt, D.C., It’s a completely linear relationship between voltage and percent power.
55
00:06:50,330 –> 00:06:56,980
High voltage power supply has got a specification of maximum output current.
56
00:06:56,980 –> 00:07:12,790
And the maximum output current occurs at 5V DC signal in. So what we get out of this, in other words, the current that’s flowing through the tube.
57
00:07:12,790 –> 00:07:19,020
Zero votes in will give me zero milliamps out.
58
00:07:19,020 –> 00:07:27,820
2.5 volts in here, will give me eleven milliamps through the system.
59
00:07:27,820 –> 00:07:38,470
And five volts will give me full 100 percent, 22 milliamps, maximum output from the high voltage power unit.
60
00:07:38,470 –> 00:07:46,540
So we’ve got a direct linear relationship between current flow and percent power.
61
00:07:46,540 –> 00:07:51,070
They’re one and the the same thing, 100 percent power. 22 milliamps.
62
00:07:51,070 –> 00:07:54,400
50 percent power. 11 milliamps.
63
00:07:54,400 –> 00:08:02,380
So it’s the percentage of the maximum output of your high voltage power supply that you’re dealing with when you specify percent power.
Transcript for High Voltage Laser Power Supply (Cont…)
64
00:08:02,380 –> 00:08:06,850
It’s not percent watts is percent current.
65
00:08:06,850 –> 00:08:09,910
So here’s what reality looks like.
66
00:08:09,910 –> 00:08:19,870
You put in zero to 100 percent power and you generate anything from zero to 22 milliamps of current flow through the tube.
67
00:08:19,870 –> 00:08:31,120
If I plot the power output against the percent power that I’m putting in, I’m going to get a linear relationship for the current through the tube,
68
00:08:31,120 –> 00:08:35,620
but I’m not going to get a linear relationship for the power out of the tube.
69
00:08:35,620 –> 00:08:41,230
So, for example, here we’ve got 50 watts maximum output for the tube.
70
00:08:41,230 –> 00:08:52,870
So if I look here. That’s 25 watts, if I look at 50 percent power, which is somewhere about here.
71
00:08:52,870 –> 00:09:05,590
That doesn’t match up with 25 watts. The watts are non-linear in relation to the percent power.
72
00:09:05,590 –> 00:09:11,380
So that’s why you cannot use the percent power to control your watts.
73
00:09:11,380 –> 00:09:19,300
You have to have a calibration chart of some sort to know what watts are related to percent power.
74
00:09:19,300 –> 00:09:24,700
One thing I want to mention is, on the power supply. You will find that there are two other terminals.
75
00:09:24,700 –> 00:09:30,010
One is called G for ground and the other one will either be W or P.
76
00:09:30,010 –> 00:09:33,550
Different manufacturers use slightly different terminology.
77
00:09:33,550 –> 00:09:41,950
But basically what we’ve got here, we’ve got water which is flowing through our tube like that,
78
00:09:41,950 –> 00:09:53,380
and that water going back to a reservoir passes by some sort of, I’ll draw it like like a water wheel, with a flow switch on it.
79
00:09:53,380 –> 00:10:00,760
So this is a normally open switch, which when the water is flowing, it will be closed.
Transcript for High Voltage Laser Power Supply (Cont…)
80
00:10:00,760 –> 00:10:07,640
And that is connected between here
81
00:10:07,640 –> 00:10:13,910
and here on a K40 or some machines.
82
00:10:13,910 –> 00:10:21,620
OK, so that is to make sure that you cannot switch the tube on if there’s no water flowing.
83
00:10:21,620 –> 00:10:28,920
It’s a safety system which is most essential, because if you run this tube without water,
84
00:10:28,920 –> 00:10:43,470
you will destroy it very quickly, within a few seconds. We’ll go into this later, but on the controller, we’ve also got G and WP.
85
00:10:43,470 –> 00:10:54,040
And generally, what you’ll find is that this system here is not connected across here, it’s connected to
86
00:10:54,040 –> 00:11:11,200
here and here. And instead of G and WP looking like that, what you’ll find is that you’ve got a link wire which is connecting those two together.
87
00:11:11,200 –> 00:11:20,260
So what we’re doing, we’re monitoring the flow with the controller and not with the high voltage power supply.
88
00:11:20,260 –> 00:11:28,930
And the high voltage power supply is being fooled into thinking that, yeah, it is switched on because we link G & WP together,
89
00:11:28,930 –> 00:11:37,600
which creates the impression that the switch is closed and the real monitoring is being done by the controller.
90
00:11:37,600 –> 00:11:43,210
But we’ll come on to the controller and its functions in another session.
91
00:11:43,210 –> 00:11:48,820
You will always have a red wire, the high voltage wire coming out of the power supply.
92
00:11:48,820 –> 00:11:55,840
Not every power supply has got a wire coming out the back.
Transcript for High Voltage Laser Power Supply (Cont…)
93
00:11:55,840 –> 00:12:07,100
Sometimes it comes out the back here and it goes to the negative side of the tube like that.
94
00:12:07,100 –> 00:12:15,560
OK, so it’s a separate black or sometimes blue wire that comes out the back of the power supply and you connect it to that pin there.
95
00:12:15,560 –> 00:12:26,020
It’s also where you would put in an ammeter. You break the wire here and you put an ammeter in just there.
96
00:12:26,020 –> 00:12:38,500
Naught to 30 milliamps is normally good enough for the range, and they’re only something like about five dollars on eBay. Now on this particular controller,
97
00:12:38,500 –> 00:12:44,740
what we’ve got, we’ve got no black wire coming out the back of this unit.
98
00:12:44,740 –> 00:12:51,700
Instead, what we’ve got is a spare connection in here.
99
00:12:51,700 –> 00:13:00,790
So we’ve got two mains cables and an earth and then we’ve got a spare terminal and that spare terminal
100
00:13:00,790 –> 00:13:09,540
there, is basically where this wire goes back into the front,
101
00:13:09,540 –> 00:13:21,080
there. So if you don’t have a black wire, that’s where it goes. If your tube doesn’t work for some reason or other, you get no power out of it.
102
00:13:21,080 –> 00:13:26,870
You need to check two things, first of all, have you got water flow?When you tried to turn the power on
103
00:13:26,870 –> 00:13:35,660
you will get a water error shown on your display pad. So that’s one thing, that will quickly tell you that you’ve got no water flowing and
104
00:13:35,660 –> 00:13:41,810
there’s either there’s a problem of some sort with this switch or with your pump. If that’s all okay,
105
00:13:41,810 –> 00:13:47,840
and you still don’t get any output power from here. That could be for and two different reasons.
106
00:13:47,840 –> 00:13:53,750
One of them could be that you’ve actually run out of carbon dioxide, as I described to you in the previous session.
107
00:13:53,750 –> 00:13:59,750
So if you’ve got a pink beam in there, you know that this thing is working properly.
Transcript for High Voltage Laser Power Supply (Cont…)
108
00:13:59,750 –> 00:14:05,780
If you don’t have a pink beam in there, there’s a pretty fair chance that there’s something wrong with this device.
109
00:14:05,780 –> 00:14:09,530
And the first thing you should do is check whether or not the fan is working.
110
00:14:09,530 –> 00:14:19,280
If the fan is working, it means you’ve got mains input working to drive the fan and something seriously has going wrong inside here.
111
00:14:19,280 –> 00:14:23,360
And the most likely serious thing is that this flyback transformer has failed.
112
00:14:23,360 –> 00:14:31,220
I have seen burnt burnt out circuit components as well. In general terms, if you’re not electronically competent, it’s a new one of these.
113
00:14:31,220 –> 00:14:35,900
Now, I promised you earlier that we’d come back and look at this thing called response time.
114
00:14:35,900 –> 00:14:42,710
It’s a very important part of the function of our laser machine with a glass tube machine.
115
00:14:42,710 –> 00:14:46,960
The controller works with all electronics.
116
00:14:46,960 –> 00:14:59,920
And the power is controlled between the H.V. power supply and the controller, with a signal which works in microsecond time scales.
117
00:14:59,920 –> 00:15:05,200
So when we say we’d like a 50 percent power, the controller says, OK,
118
00:15:05,200 –> 00:15:13,240
now draw this line with 50 percent power and switch on now, because it sees the beginning of the line.
119
00:15:13,240 –> 00:15:21,310
So the percent power and the on off signal gets sent at exactly the same time.
120
00:15:21,310 –> 00:15:31,280
The percent power, is instantly switched on, ready to limit the control of current in this circuit here.
121
00:15:31,280 –> 00:15:41,870
But we haven’t yet switched the tube on, because instantly we tell the HV power supply to switch the high voltage on.
122
00:15:41,870 –> 00:15:45,710
But before the current can flow through the circuit, remember,
123
00:15:45,710 –> 00:15:54,770
we got to have an ionized beam and to create the ionized beam, we have to have kilovolts.
124
00:15:54,770 –> 00:15:58,480
And you remember me pointing out that white thing in the back of the power supply,
Transcript for High Voltage Laser Power Supply (Cont…)
125
00:15:58,480 –> 00:16:09,500
and I said that it was capable of only responding in millisecond timescales. One millisecond later than the on/off signal.
126
00:16:09,500 –> 00:16:18,590
We’ve now got sufficient voltage in here to allow 90 percent of the power to be flowing in this circuit.
127
00:16:18,590 –> 00:16:22,970
So once we’ve got the laser beam switched on, it can respond very quickly.
128
00:16:22,970 –> 00:16:27,710
The thing that doesn’t happen quickly is switching the laser tube on.
129
00:16:27,710 –> 00:16:29,660
And what do we doing all the time we’re running?
130
00:16:29,660 –> 00:16:39,000
Every time we generate a new signal, we switch the laser beam off. So that we can move to the next part and cut the next part and then we switch it on.
131
00:16:39,000 –> 00:16:46,970
Well, that’s not too bad when you’re running a cutting circuit because things are moving basically quite slowly.
132
00:16:46,970 –> 00:16:57,740
The thing that really starts worrying us is when we start moving to scanning or engraving. Here, we’ve got our head with the lens in it and we want to scan
133
00:16:57,740 –> 00:17:08,090
a pattern at 400 millimeters a second. OK, so this is the line that the controller thinks we’re going to try and produce.
134
00:17:08,090 –> 00:17:18,440
So it moves the head to this position here and then it says to the controller, OK, switch on now because I want to draw a line.
135
00:17:18,440 –> 00:17:24,800
We’re traveling at 400 millimeters a second and one second is a thousand milliseconds.
136
00:17:24,800 –> 00:17:34,130
So if we take 400 millimeters and divide it by a thousand, in one millisecond, I’m going to travel naught point four of a millimeter.
137
00:17:34,130 –> 00:17:44,610
So that means if I’m trying to draw blue lines, scan lines like this, the first scan line is going to be point four of a millimeter slow.
138
00:17:44,610 –> 00:17:46,400
It’s going to finish correctly,
139
00:17:46,400 –> 00:17:54,200
and then it’s going to jump down to the next scan line and come back and it’s going to start point four millimeters slow.
140
00:17:54,200 –> 00:18:02,340
And so it’s going to happen every time we scan backwards and forwards. So we’re not going to finish up with a nice blue scanline pattern like this.
Transcript for High Voltage Laser Power Supply (Cont…)
141
00:18:02,340 –> 00:18:06,500
We’re going to finish up with a raggedy pink scanline pattern like this.
142
00:18:06,500 –> 00:18:10,880
Your image is going to be very fuzzy around the edges because of this effect.
143
00:18:10,880 –> 00:18:16,460
If you slow down to 200 millimeters a second, then you’re only going to have a 0.2mm error.
144
00:18:16,460 –> 00:18:21,580
If you slow down to about 10 millimeters a second, it’s going to be negligible.
145
00:18:21,580 –> 00:18:24,130
But you can’t scan at 10 millimeters a second.
146
00:18:24,130 –> 00:18:33,310
There are parts of the system in the programing system called reverse scanning offset, to try and compensate for this,
147
00:18:33,310 –> 00:18:41,350
but I’m not going to go into that at the moment. All I want to show you is how important it is that the response time of the power supply can actually
148
00:18:41,350 –> 00:18:47,890
mess around with the relationship between the start point, actual and the start point program.
149
00:18:47,890 –> 00:18:54,640
Now, when we move on to bitmaps, things begin to change quite dramatically.
150
00:18:54,640 –> 00:19:00,650
A bitmap could be composed of something like this.
151
00:19:00,650 –> 00:19:06,980
It could be a pixel, which is naught point one millimeters wide, where did I get that from?
152
00:19:06,980 –> 00:19:13,560
Well, if I’ve got an image which is set to 254 pixels per inch.
153
00:19:13,560 –> 00:19:18,810
It means every pixel could be naught point one millimeters wide.
154
00:19:18,810 –> 00:19:30,450
Which is 254 dots per inch, so we need to switch the laser on and off at this rate, 254 dots per inch.
155
00:19:30,450 –> 00:19:37,660
It’s it’s a slight exaggeration because it’s actually one dot then off, one dot off.
156
00:19:37,660 –> 00:19:44,340
So it’s actually only half that amount, about a 127. Let’s just say we’re trying to run this at 400 millimeters a second.
157
00:19:44,340 –> 00:19:50,220
This scan of on off, on, off, on off, on off the computer is going to say right now switch on now.
158
00:19:50,220 –> 00:20:01,170
So it’ll switch on, but nothing happens until point four of a millisecond later or point four of a millimeter later.
Transcript for High Voltage Laser Power Supply (Cont…)
159
00:20:01,170 –> 00:20:06,510
One, two, three, four. And of course, it switches off OK.
160
00:20:06,510 –> 00:20:12,390
And then it’s going to take one, two, three, four to switch on the next one.
161
00:20:12,390 –> 00:20:24,460
So hang on. Look how many signals I’ve got. Look how many pixels I’ve missed, so I’m not going to do a very good job of replicating that pattern.
162
00:20:24,460 –> 00:20:30,820
Let’s just stay at 400 millimeters a second for a moment, because we’ve got another problem.
163
00:20:30,820 –> 00:20:36,340
We’ve told the power supply to switch on at this point here.
164
00:20:36,340 –> 00:20:45,270
And we know that it’s going to take point four of a millisecond. Or point four millimeters to switch on.
165
00:20:45,270 –> 00:20:50,190
So it starts to switch on and then it gets told to switch off.
166
00:20:50,190 –> 00:20:55,410
So if we run too fast, we’re not actually going to produce any pixels at all.
167
00:20:55,410 –> 00:21:07,780
So here’s our demand. Whatever that demand current is, a certain number of milliamps, and here’s zero, the signal isswitched off.
168
00:21:07,780 –> 00:21:13,330
So if we run at a100 millimeters a second, what it means is it starts off at zero.
169
00:21:13,330 –> 00:21:20,650
It might possibly get up to 90 percent of what we’re after within one millisecond.
170
00:21:20,650 –> 00:21:28,300
Like that, and then it would drop off. And then there’ll be no signal.
171
00:21:28,300 –> 00:21:33,460
And then we shall switch on again, and it possibly might take
172
00:21:33,460 –> 00:21:38,110
the same amount of time and we won’t have a full millisecond of burn.
173
00:21:38,110 –> 00:21:50,590
We’ll only have a very short period here, where we might be able to experience enough burn to produce a dot of some sort.
174
00:21:50,590 –> 00:21:56,580
Now, the dots will be the right size apart, but they won’t be very strong.
Transcript for High Voltage Laser Power Supply (Cont…)
175
00:21:56,580 –> 00:22:06,210
If we want stronger dots, we shall have to drop this to something like 50 millimeters a second and at 50 millimeters a second,
176
00:22:06,210 –> 00:22:11,250
then it means that we should be able to get this to rise up much quicker like this.
177
00:22:11,250 –> 00:22:20,710
And maybe we shall then have enough power to produce a much bigger dot every time.
178
00:22:20,710 –> 00:22:27,130
This gets quite complicated, the way in which the power supply controls what you can do with this machine.
179
00:22:27,130 –> 00:22:34,870
So you can’t just go and think that pushing buttons on this machine is going to make it work, how you imagine it will work?
180
00:22:34,870 –> 00:22:43,030
There are bits of this machine which will slow you down and cause you to scratch your head if you don’t understand what’s going on.
181
00:22:43,030 –> 00:22:51,970
That’s why I’m taking the time to explain to you that you can’t just run at 600 millimeters a second with a thousand DPI.
182
00:22:51,970 –> 00:22:55,630
The power supply just won’t support that rate of putting dots down.
183
00:22:55,630 –> 00:23:00,010
It can’t switch on and off quick enough, we’ve got a little bit technical there,
184
00:23:00,010 –> 00:23:10,050
but you have to understand the power supply is a limiting factor on a glass tube machine. Now in reality,
185
00:23:10,050 –> 00:23:16,230
most power supplies are actually at least 50 percent better than the spec. My power supplies, on
186
00:23:16,230 –> 00:23:21,660
both my machines are capable of running four times faster than the specification states.
187
00:23:21,660 –> 00:23:27,900
You can’t say how good a power supply is going to be other than it must meet the specifications.
188
00:23:27,900 –> 00:23:32,280
Now, if you bought an eBay machine and it’s fitted with a power supply,
189
00:23:32,280 –> 00:23:37,820
there’s a pretty fair chance that that power supply is a B-Grade power supply.
190
00:23:37,820 –> 00:23:45,920
And it’s B-Grade because it failed the one thing that you most need, which is its response time specification.
191
00:23:45,920 –> 00:23:52,420
It’ll deliver the power, it’ll deliver the voltage, but what it won’t do a switch on and off quick enough.
192
00:23:52,420 –> 00:24:02,560
And on that bombshell, we will end our discussion about power supplies.
Transcript for High Voltage Laser Power Supply